9 - 20
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description (page 9-1) for additional
information. Minimum and Maximum lengths = 0-80. Minimum Default = 3, Maximum Default = 80.
Code 128 Code Page
Code pages define the mapping of character codes to characters. If the data received does not display with the proper
characters, it may be because the bar code being scanned was created using a code page that is different from the one the
host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were
created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from
the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
ISBT 128
ISBT is a variation of Code 128 that supports concatenation of neighboring symbols on a blood product label. Use the bar
codes below to turn ISBT 128 concatenation on or off. Default =Off.
Minimum Message Length
Maximum Message Length
Code 128 Code Page
On
* Off