Values for some programming fields are system-wide (global), and some can be different for each partition (partition-
specific).
The partition-specific programming fields are automatically skipped when programming the global fields. If
the system has only 1 partition, the partition-specific fields are not automatically skipped.
To program system-wide data fields, perform the following steps:
1.
Enter Program Mode: Installer Code + 8 0 0 0.
The following display appears:
Program Mode
Fill # View 00
2.
If the control has not been programmed before, enter 97 to load factory defaults.
3.
Press [] and enter the first field number to be programmed (for example, 00, Installers Code). Make the desired entry.
When the field is complete, the keypad beeps three times and advances to the next field. If you do not want to change
the next field, press [] and enter the next field number to be programmed.
First Page of fields
(00 - 90)
To change to the next page of fields, press 94. To return to the previous page of fields, press 99.
4.
Press 99 or 98 to exit Program Mode.
NOTE: If the number of digits that you enter in a data field is fewer than the maximum permitted (for example, a phone
number), the keypad displays the last entry and waits. To proceed, enter [] + the next data field you wish to
program.
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
P
P
a
a
r
r
t
t
i
i
t
t
i
i
o
o
n
n
-
-
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
D
D
a
a
t
t
a
a
F
F
i
i
e
e
l
l
d
d
s
s
To program partition-specific data fields once in Program Mode, do the following:
1.
Enter Program Mode: Installer Code + 8 0 0 0.
2.
Press
91, which will prompt you for the partition number desired.
3.
Enter a partition-specific field number (e.g., 09) to begin programming.
When the first field’s entry is completed, the next partition-specific field is automatically displayed. When all
partition-specific fields are programmed, the system returns to the global programming fields (page 1
fields).
4.
Repeat this procedure for each partition in the installation.
NOTE: To return to the global program fields before finishing all fields, enter any global field number.
Programming Partition-Specific Fields
1. Press 91 to select a partition.
2. Enter the partition to be programmed.
3. Enter a partition-specific field number and make entry.
4. After partition-specific fields are programmed,
5. Press 91 to select next partition.
6. Enter any global field number to return to the global fields at any time.