If you pressed the D key previously to enter defaults for 5804 and/or 5804BD wireless keys, the following screens appear:
PROMPT EXPLANATION
FROM TEMPLATE
1–6 1
Enter template number (16).
5834-4
5804BD
Template 1
Loop
Function
ZT
Template 4
Loop
Function
ZT
1
No Response
23
1
No Response
23
2
Disarming
22
2
No Response
23
3
Arm AWAY
21
3
Arm AWAY
21
4
No Response
23
4
Disarming
22
Template 2
Loop
Function
ZT
Template 5
Loop
Function
ZT
1
No Response
23
1
No Response
23
2
Disarming
22
2
Arm STAY
20
3
Arm AWAY
21
3
Arm AWAY
21
4
Arm STAY
20
4
Disarming
22
Template 3
Loop
Function
ZT
Template 6
Loop
Function
ZT
1
24-Hour Panic
07
1
24-Hour Panic
07
2
Disarming
22
2
Arm STAY
20
3
Arm AWAY
21
3
Arm AWAY
21
4
Arm STAY
20
4
Disarming
22
Select from templates. Press [] to display template (template 1 shown selected).
NOTE: If necessary, press [#] to back up and re-enter template number.
Press [#] if you want to return to zone attributes screen.
L 01 02 03 04
ZT 23 22 21 23 1
When you press [], the selected template is displayed.
Top line of display represents loop numbers; bottom line represents zone type.
Press [] to accept template.
PARTITION
1
Enter partition number for wireless key.
Press [] to continue.
ENTER ZONE NO
000 = QUIT 024
Example of zone number
suggested by the system.
This indicates that zones
24, 25, 26, and 27 are
available.
The system searches for the highest available, consecutive 4-zone group (the four zones required for
the 5834-4 and 5804BD), and displays the lowest zone number of the group.
If you want to start at a different zone number, enter the zone desired and press [].
If that zone number is displayed, the system has the required number of consecutive zones
available, beginning with the zone you entered. If not, the system again displays a suggested
zone that can be used.
If the required number of consecutive zones is not available at all, the system will display “000.”
Press [] to accept.
024 INPUT S/N L
AXXX-XXXX 1
To enter the serial number:
Press and release a button on the wireless key.
OR
1. Manually enter the 7-digit serial number printed on the device’s label.
2. Press [] to accept serial number. The system checks for a duplicate.
3. If a duplicate exists, a long error beep will sound and the serial number reverts to all “X”s allowing
you to re-enter the serial number.
Use the [A] key to move forward within the screen, and the [B] key to back up.
XMIT TO CONFIRM
PRESS TO SKIP
If you entered YES previously at the SET TO CONFIRM prompt (see first prompt following entry into the
Expert Programming Mode), the display on the left appears.
To confirm, activate the button on the wireless key that corresponds to this zone.
Entd A022-4063
Rcvd A022-4064
If the serial number transmitted does not match the serial number entered, a display similar to the
one at the left appears.
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e.,
summary display does not appear), press the [#] key and then enter the correct serial number.
Activate the button on the wireless key again after re-entering the serial number.
ENTER ZONE NO
000 = QUIT 028
If the serial number transmitted matches the serial number entered, the system will beep 3 times and
revert to the "Start Zone No." prompt and will show the lowest numbered zone of the next available 4-
zone group (4 consecutive zones) that is available for programming.
After all the wireless keys have been entered, enter 000 for the zone number to quit.