EasyManua.ls Logo

Honeywell VISTA-128BPT - System Overview; General System Introduction

Honeywell VISTA-128BPT
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
S
S
E
E
C
C
T
T
I
I
O
O
N
N
:
:
1
1
S
S
I
I
A
A
C
C
P
P
-
-
0
0
1
1
T
T
A
A
B
B
L
L
E
E
S
S
I
I
A
A
C
C
P
P
-
-
0
0
1
1
Q
Q
u
u
i
i
c
c
k
k
R
R
e
e
f
f
e
e
r
r
e
e
n
n
c
c
e
e
C
C
h
h
a
a
r
r
t
t
The minimum required system for SIA CP-01 is a VISTA-128BPTSIA Control, one of the following model keypad; 6160,
TUXS, TUXW, 6280S, or 6280W and a UL Listed Bell.
R
R
e
e
q
q
u
u
i
i
r
r
e
e
d
d
S
S
I
I
A
A
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
L
L
o
o
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Item Feature Range
Shipping
Default
SIA Requirement*
09
Entry Delay # 1 02 15 multiplied by 15 seconds
00 = 240 sec (4 minutes)
30 Seconds` At least 30 Seconds **
10
Exit Delay #1 03 15 multiplied by 15 seconds 60 Seconds 60 Seconds
11
Entry Delay # 2 02 15 multiplied by 15 seconds
00 = 240 sec (4 minutes)
30 Seconds At least 30 Seconds **
12
Exit Delay #2 03 15 multiplied by 15 seconds 60 Seconds 60 Seconds
28
Power Up in Previous
State
0 = no
1 = yes
Yes Yes
57
Dynamic Signaling
Priority
0 = primary dialer
1 = Communicator as first
reporting destination
0 (primary dialer) 0 (primary dialer)
84
Swinger Suppression 01-06 = 1-6 alarms 2 alarms 1 alarm
88
Abort Window Time (for
non-fire zones)
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
30 Seconds At least 15 Seconds **
121
Exit Time Reset 0 = no
1 = Resets Exit Delay to
programmed value
after zone is closed
and then faulted prior
to end of exit delay.
1 (Enabled) 1 (Enabled)
122
125
Cross Zoning Zone 001 250
000, 000 = Disabled
Disabled Enabled and two (or more)
zones programmed
142
Call Waiting Defeat 0 = no
1 = yes
Disabled (0) Enabled if user has call
waiting
1
61
Abort Verify 0 = Disable
1 = Enable
Enabled Enabled
R
R
e
e
q
q
u
u
i
i
r
r
e
e
d
d
S
S
I
I
A
A
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
Item
Feature
Range
Shipping
Default
SIA
Requirement*
Zone Programming
Auto Stay Zone, Zone
type 04 has this
feature enabled by
default
Auto Stay Arm or Occupied
Premises
0 = Disable
1 = Enable
1 (Enabled) Enabled
Zone Programming
(Abort Window
Enable)
Abort Window (for non-fire
zones)
0 = no abort window
1 = yes, use abort window
according to 88
selection
1 = yes Yes (all non-fire
zones)
Zone Programming
(Swinger Suppression
Enable)
Swinger Suppression Enable 0 = no suppression
1 = yes, suppress alarms
according to 84
selection
Yes
(enabled)
Yes (enabled (all
zones))
Zone Programming
Tamper Option
Fire Alarm Verification For Zone Response Type
16 (Fire) tamper selection
must be set to “0”
Disabled Enabled unless
sensors can self
verify

Table of Contents

Other manuals for Honeywell VISTA-128BPT

Related product manuals