VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
P
P
a
a
r
r
t
t
i
i
t
t
i
i
o
o
n
n
-
-
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
F
F
i
i
e
e
l
l
d
d
s
s
(Duplicate this page for each partition in the installation.)
To program these fields:
1. Press 91 to select a partition.
2. Enter a partition-specific field number (ex. 09).
3. Make the required entry.
4. Repeat steps 1-3 for each partition in the system.
P
P
A
A
R
R
T
T
I
I
T
T
I
I
O
O
N
N
#
#
_
_
_
_
_
_
_
_
P
P
R
R
O
O
G
G
R
R
A
A
M
M
F
F
I
I
E
E
L
L
D
D
S
S
1st Page Fields
06 QUICK EXIT [1] A E
1=enable; 0=disable
Must be 0 for UL installations.
09 ENTRY DELAY #1 [02] A | E
00, 02-15 times 15 seconds.
Maximum 03 for UL Listed installations.
10 EXIT DELAY #1 [04] A | E
00, 02-15 times 15 seconds.
Maximum 04 for UL Listed installations.
11 ENTRY DELAY #2 [02] A | E
00, 02-15 times 15 seconds.
Maximum 03 for UL installations.
12 EXIT DELAY #2 [08] A | E
00, 02-15 times 15 seconds.
Maximum 04 for UL installations.
13 ALARM SOUNDER DURATION [04] A | E
01-15 times 2 minutes.
Must be minimum 16 minutes for UL installations.
16 CONFIRMATION OF ARMING DING [0] A E
1=enable; 0=disable.
NOTE: If using a keyfob, when the button is pressed,
either for arming or disarming, the bell will ding indicating
that the button is working.
Must be "1" for UL installations.
22 KEYPAD PANIC ENABLES [111] A E AA E AA E
1=enable; 0=disable 995 996 999
23 MULTIPLE ALARMS [1] A E
1=yes; 0=no.
Must be 1 for UL installations.
(Option not displayed in SIA, always enabled.)
29 QUICK ARM [1] A E
1=yes; 0=no
32 PRIM. SUBS. ACCT #
A | E AA | E AA | E AA | E AA | E AA | E AA | E AA | E
AA | E AA | E
Enter 00-09; B-F (11-15) [15 15 15 15 15 15 15 15 15 15]
38 PREVENT ZONE XXX BYPASS [000] A | | E
001-250; 000 if all zones can be bypassed
39 ENABLE OPEN/CLOSE REPORT [1] A E
FOR INSTALLER CODE
1=enable; 0=disable
84 SWINGER SUPPRESSION [01] A | E
01-14 alarms;
Must be "00" (disabled) for UL installations.
NOTE: For SIA only options 01 through 06 are available.
85 ENABLE DIALER REPORTS FOR PANICS & DURESS
1=enable; [0=disable] A
E995E
AA
E996E
AA
E999E
AA
EDuressE
88 BURG. ALARM COMM. DELAY [1] A E
1=30 seconds; 0=no delay.
Must be "0" for UL installations.
90 SEC. SUBS. ACCT #
A | E AA | E AA | E AA | E AA | E AA | E AA | E AA | E
AA | E AA | E
Enter 00-09; B-F (11-15) [15 15 15 15 15 15 15 15 15 15]
2nd Page Fields
1
18 AFFECTS LOBBY [0] A E
Enter 1 if this partition affects the common lobby; enter 0
if it does not.
1
19 ARMS LOBBY [0] A E
Enter 1 if arming this partition attempts to arm lobby;
enter 0 if it does not
1
26 PANIC BUTTON OR SPEEDKEY
[00, 00, 00, 00] A
|
EAE
A
A
|
EBE
A
A
|
ECE
A
A
|
EDE
Enter speedkey macro # (01-32) to use keys A-C for
macro. Otherwise enter 00 to use as panic. For D key,
enter macro # or 00 to select macro when key is pressed.
143 PERM. KEYPAD BACKLIGHT [0] A E
1=enable; 0=disable; When disabled the display lights
when any key is pressed, and turns off after period of
keypad inactivity.
NOTE: This field affects only standard keypads, not
graphic/touch-screen keypads.