51
SECTION 3: DATA FIELD DESCRIPTIONS
R
R
e
e
s
s
t
t
o
o
r
r
e
e
/
/
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
o
o
r
r
y
y
C
C
o
o
d
d
e
e
s
s
PROMPT EXPLANATION
RESTR, SUPV. CODE
1 = YES 0 = NO 0
Press [1] (Y) to enter Restore and Supervisory Codes for zones.
ENTER ZN FOR GRP
000 = QUIT 001
Enter one zone for each group of 16 zones:
988: 2
nd
Wireless Receiver
st
997: Short on V-Plex® Loop
E
E
C
C
P
P
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
i
i
o
o
n
n
N
N
o
o
t
t
e
e
s
s
:
:
Connections are checked every 45 seconds, which provide the ability to report bad connections and
other supervisory events of ECP devices (see Installation and Setup Guide for troubleshooting steps).
Zones 800-830, follow the device number, example is address 03 will show zone 803 in trouble.
NOTES:
• Supervision of the 800 zones are enabled by entering a zone type for that zone in Zone
Programming.
• No matter what zone type is entered, the response is a 24hr Trouble with local (keypad) trouble
sounding and reports if trouble reporting is enabled for that group of zones.
• The system reports/logs the supervisory/tamper restore as True Restore (See ∗89).
Partition Displays:
Check on System devices display as follows:
• Relay board, ECP Communicator, etc. show only on partition one,
• Check on a Keypad address will show only on the partition the keypad is assigned to
• Check on Receivers will show on all partitions that have RF zones assigned.
Reports:
• E333 Expander module Failure (missing)
• E341 Expander module Tamper (cover or base Tamper activated)
ALARM RESTORE
GRP 001-016 00
Enter the first digit of the Alarm Restore Report Code for this group of zones (double-digit entry). The
second digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report
Code for each zone (if programmed).
Press [∗] to continue.
TROUBLE
GRP 001-016 00
Enter the first digit of the Trouble Report Code for this group of zones (double-digit entry). The second
digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for
each zone (if programmed).
Press [∗] to continue.
TROUBLE RESTORE
GRP 001-016 00
Enter the first digit of the trouble restore code (single-digit entry) and press [∗]. The second digit (for
two-digit reporting formats) is automatically the ID (second) digit of the alarm report code for each zone
(if programmed).
Press [∗] to continue.
BYPASS
GRP 001-016 00
Enter the first digit of the Bypass Report Code (double-digit entry) and press [∗]. The second digit (for
two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for each
zone (if programmed).
Press [∗] to continue.
BYPASS RESTORE
GRP 001-016 00
Enter the first digit of the Bypass Restore Report Code (double-digit entry) and press [∗]. The second
digit (for two-digit reporting formats) is automatically the ID (second) digit of the Alarm Report Code for
each zone (if programmed).
Press [∗] to continue.
ENTER ZN FOR GRP
000 = QUIT 017
Enter one zone for each group of 16 zones. When you are finished entering Restore and Supervisory
Codes for all zone groups, enter 000 and the control will prompt you to QUIT REPORT MENU.
Press [∗] to continue.