Verify the following programming is preset before continuing:
One partition is programmed by default. If multiple partitions are desired, filed 2
00 must be configured.
If programming wireless transmitters, all wireless receivers must be programmed (see “Device Programming”)
and wired to the ECP Bus (see “Installation and Setup Guide”).
S
S
y
y
n
n
t
t
a
a
x
x
After programming all system related programming fields:
1. Press #93 to display the first choice of the menu driven programming functions.
2. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. (Pressing 0 will display the next choice in
sequence.)
NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the
event log capacity, use the VISTA-250BPT’s features. See page 1-2 of this manual for the table listing the
differences between the VISTA-128BPT and the VISTA-250BPT control panels.
UL
For UL installations, verify that the audio alarm verification feature is disabled.
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93
Enters Menu mode
[]
Serves as ENTER key. Press to have keypad accept entry and move forward.
[#]
Backs up to previous screen.
0
Press to answer NO
1
Press to answer YES
001-009
All data entries are either 2-digit or 3-digit entries.
000
Exits menu mode, back into field programming mode, when entered at the first question for each category.
Menu selections are as follows:
PROMPT EXPLANATION
ZONE PROG?
1 = YES 0 = NO 0
For programming the following:
Zone Number
Zone Response Type
Partition Number for Zone
Dialer report code for zone
Input Device Type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.
Zone Attributes (e.g., Arm w/Fault, Silent, etc.)
EXPERT MODE?
1 = YES 0 = NO 0
Same as Zone Programming except:
Done with a minimum number of keystrokes.
Can program wireless keys using pre-defined templates.
NOTE: Some of the zone attributes cannot be programmed in the Expert Mode, only in Zone
Programming.
REPORT CODE PROG?
1 = YES 0 = NO 0
For programming the following:
Alarm report codes for zones
Restore & Trouble codes
All other system report codes
ALPHA PROG?
1 = YES 0 = NO 0
For entering alpha descriptors for the following:
Zone Descriptors
Installer's Message
Custom Words
Partition Descriptors
Relay Descriptors
DEVICE PROG?
1 = YES 0 = NO 0
For defining the following device characteristics for addressable devices, including keypads, RF receivers
(5881), output relay modules (4204), and ECP Communications Device.
Device Address
Device Type
Keypad Options (incl. partition assignment)
RF House ID
ECP Communicator Options (incl. programming communications device)