39
SECTION 3: DATA FIELD DESCRIPTIONS
145 EXIT DELAY SOUNDING [1] A E
1=enable; 0=disable; Produces quick beeping during exit
delay if enabled.
NOTE: Must be “1” for UL/ULC installations.
NOTE: See page 32, “SOUND OPTION”, prompt for
disabling the entry/exit beeps on individual
keypads.
(Option not displayed in SIA, always enabled.)
147 CHIME ON EXT. SIREN [0] A E
1=enable; 0=disable
152 SEND CANCEL IF ALARM + OFF [1] A E
1=no restriction; 0=within Bell Timeout period only
176 ACCESS CONTROL RELAY BY PART.[00] A | E
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-96; 00=none.
Must be "00" for UL installations.
3rd Page Fields
2
05 AUTO-ARM DELAY [15] A | E
Enter the time between the end of the arming window and
the start of auto-arming warning period, in values of 1-14
times 4 minutes 00=instant; [15=no auto arm at all]. When
this delay expires, the Auto-Arm Warning Period begins.
206 AUTO-ARM WARNING PERIOD [15] A | E
This is the time during which the user is warned to exit the
premises prior to the auto-arming of the system (beeps
every 15 seconds; "ALERT" displayed). Enter 01-15
minutes. 00=instant at end of arming delay.
207 AUTO-DISARM DELAY [15] A | E
This is the time between the end of the disarming window
and the start of auto-disarming. Enter 01-14 times 4
minutes; 00=instant at end of window; 15=no auto-disarm
208 ENABLE FORCE ARM FOR AUTO-ARM [0] A E
0=disable; 1=enable
209 OPEN/CLOSE REPORTS BY EXCEPTION [0] A E
1=enable; 0=disable; If enabled only openings and
closings occurring outside the scheduled opening/closing
windows will trigger dialer reports. Opening reports will
also be suppressed during the closing window, in order to
prevent false reports when the user arms the system and
then re-enters the premises to retrieve a forgotten item.
210 ALLOW DISARMING ONLY DURING [0] A E
ARMING/DISARMING WINDOWS
See system-wide field 211 if enabling field 210. This
feature adds high security to the installation.
0=disable; 1=enable
218 ENABLE GOTO FOR THIS PARTITION [1] A E
1=Allow log-on from other partitions; 0=disable
222 DISPLAY FIRE ALARMS OF [0] A E
OTHER PARTITIONS
0=No; 1=Yes
2
23 DISPLAY BURG, PANIC AND CO [0] A E
ALARMS OF OTHER PARTITIONS
0=No; 1=Yes
224 DISPLAY TROUBLES OF OTHER [0] A E
PARTITIONS
0=No; 1=Yes
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0]
+ [0] + [0]
To set standard defaults, press 97
To change to next page of program fields, press 94
To return to previous set of fields, press 99
To erase account and phone number field entries,
press [] + field number + []
To assign zone descriptors, press #93 + follow menu
prompts
To add custom words, press #93 + follow menu
prompts
To enter Installer's Message, press #93 + follow menu
prompts
To exit program mode, enter 99 OR 98: 99 allows
re-access to programming mode by installer code. 98
prevents re-access to programming mode by installer
code. Note that if local programming lockout is set via
downloading, programming mode cannot be entered at
the keypad. In the event that local programming is
required after the lock-out, setting the location in
Compass will open a 24-hour window for programming
when the Master code + #65-command is entered. The
24-hour window counts down and then locks out local
programming until the next Master code + #65-
command is entered.