All report codes are entered using #93 Menu Mode Programming, either through Report Code Programming, or through
Zone Programming while entering other zone information. In the control, reports are divided into six categories. These
categories represent the main menu options in Report Code Programming. Reports and the categories in which they are
found are as follows:
ALARM CODES
RESTR, SUPV. CODES
SYSTEM GROUP #1
Zone Alarm Reports Alarm Restore
Trouble
Trouble Restore
Bypass
Bypass Restore
Closing (arm AWAY)
Opening (disarm)
System Low Battery
Low Battery Restore
AC Loss
AC Restore
Periodic Test
Power
Cancel
Program Tamper
SYSTEM GROUP #2
SYSTEM GROUP #3∗∗
SYSTEM GROUP #4
Arm STAY
Time Set, Log Reset
Telco Trouble
Exit Error by Zone
Recent Close
Early Open
Early Close
Late Open
Late Close
Failed to Open
Failed to Close
Auto-Arm Failed
Schedule Change
Walk-Test Start
Walk-Test End
Programs in groups of 16 zones at a time.
∗∗ See “Scheduling Options” in the “Installation and Setup Guide” for more information.
The programming sequence that follows assumes that you will be entering all reports for the system at one time. In
actuality, you may skip from one main menu option to another by pressing 0 (N) at each main menu option. To enter
report codes, do the following:
Enter Program Mode: [Installer Code] + 8 0 0 0. Then press #93. Enter 0 (N) at each main menu option until the Report
Code Programming option is displayed.
PROMPT EXPLANATION
REPORT CODE PROG
1 = YES 0 = NO 0
Press 1 (Y) to enter to Report Code Programming.
Z
Z
o
o
n
n
e
e
A
A
l
l
a
a
r
r
m
m
R
R
e
e
p
p
o
o
r
r
t
t
s
s
PROMPT EXPLANATION
ALARM, ID DIGIT?
1 = YES 0 = NO 0
Press [1] (Y) to enter Alarm Report Codes for zones. Press [0] (N) to skip to the next main menu option.
ENTER ZONE NO.
000 = QUIT 001
Enter the zone number for which you are entering the report code.
Press [] to continue.
001 REPORT CODE
1st 00 2nd 00 00
Enter the first digit of the Alarm report code (double-digit entry) and press []. Enter the 2nd digit of the
Alarm Report code.
Press [] to continue.
ENTER ZONE NO.
000 = QUIT 001
Enter the zone number for which you are entering the report code. When all zone Alarm Codes have
been programmed, enter 000 to Quit.
Press [] to continue.
QUIT REPORT MENU
1 = YES 0 = NO 0
If you have completely finished entering report codes, press [1] (Y) to quit Report Code Programming. If
you wish to enter other system report codes, enter 0 (N).
Press [] to continue.