Expert mode allows you to program zones using the minimum number of screens and keystrokes.
Expert Mode Zone Programming does not provide the capability to program some of the zone’s
attributes, such as Arm w/Fault, Vent Zone, STAY mode, Auto-STAY, Bypass Group, etc. If you want to
program a zone for any of these attributes, you must use Zone Programming.
Enter the Programming mode with [Installer Code] + 8 0 0 0
Before programming your zones, do the following:
1. Program field 200: Number of Partitions.
2. Enable your RF Receiver in Device Programming menu mode.
To program your zones, press #93 to display the "ZONE PROG?" prompt. Enter “0” (NO) to each prompt until the “EXPERT
MODE?” prompt appears.
PROMPT EXPLANATION
EXPERT MODE?
1 = YES 0 = NO 0
Press 1 to enter Expert mode.
SET TO CONFIRM?
0 = NO 1 = YES 0
This prompt appears once upon entering Expert Mode.
If you select “Yes,” Confirmation prompts will be displayed after the device’s Serial and Loop numbers
have been entered later.
Zn ZT P RC In L
001 03 1 10 HW
-
A summary display appears, showing zone 001’s current programming or default values. The curser
flashes under Zn.
Zn ZT P RC In L
010 03 1 10 RF 1s
Enter the desired 3-digit zone number and press [].
NOTE: If you want to exit the Expert mode, enter “000” + [
].
If an “s” appears after the loop number, it indicates that the transmitter’s serial number has been
enrolled.
Use the [D] key to enter and duplicate wireless keys (see “Entering Wireless Keys” later)
Zn ZT P RC In L
010 03 1 10 RF
-
Enter all zone information except for Loop number, or press “C” to copy the zone information on this
screen from the last saved zone (including Loop).
ZT = Zone Type
P = Partition
RC = Report Code
In = Input Device Type
L = Loop number to which the sensor is connected.
NOTE: Pressing the [C] copies the zone information from the last saved zone which includes the
input type. Verify this information is correct for this zone.
On this screen:
Use the [A] key to move to the right.
Use the [B] key to move to left and to back up to “ZT” field.
Press [] to accept the existing or newly-entered zone information.
ZN B M V A C E AD
010 1 0 1 1 01
Enter the remainder of the zone’s information, or press the [C] key to copy the zone attributes on this
screen from the last saved zone.
B = Not Applicable
M = Not Applicable
V = V-Plex Relay? (only used if “In” = 6)
AC = Access Point (only used if ZT = 27, 29 or In = 6,
11, 12, 13)
E = Entry or Exit? (only used if ZT = 27)
AD = Address (only used if “In” = 9)
If “In” = 9, enter the Device Address
NOTE: Pressing the [C] copies the zone attributes from the last saved zone. Verify the attributes
for this zone are correct.
On this screen:
Use the [A] key to move to the right.
Use the [B] key to move to left and to back up to “V” field.
Press [] to accept existing information.