53
SECTION 3: DATA FIELD DESCRIPTIONS
S
S
y
y
s
s
t
t
e
e
m
m
G
G
r
r
o
o
u
u
p
p
#
#
3
3
C
C
o
o
d
d
e
e
s
s
PROMPT EXPLANATION
SYSTEM GROUP #3 ?
1 = YES 0 = NO 0
To enter System Group #3 codes, press [1] (Y).
EARLY OPEN
1st 00 2nd 00
Enter the first digit of the displayed reporting option Code. Press []. Enter the second digit of the report
code. If the user number is desired as the second digit, enter 01 (not necessary for Contact ID format)
Press [] to continue.
Enter the rest of the codes in the same manner. Other codes in System Group #3 are:
Early Open:
NOTE: Early Opening reports are sent if system is manually disarmed before opening window
begins. (Reports an E451)
Early Close
NOTE:
Early Closing reports are sent if manual arming occurs before the closing window begins. (Reports
an R451)
Late Open
NOTE: Late Opening reports are sent if disarm occurs after the opening window expires (Reports
an E452)
Late Close
NOTE: Late Closing reports are sent if system is manually armed after the closing window expires.
(Reports an R452)
Failed to Open
NOTE: Fail to Open reports are sent if manual disarming has not occurred at expiration of
opening window. (Reports an E453)
Failed to Close
NOTE: Fail to Close reports are sent if manual arming has not occurred at expiration of closing
window. (Reports an R454)
Auto-Arm Failed
NOTE: Only occurs when force arm is enabled and occurs at the “End or Exit” time, when a zone is
faulted. (Reports an E455)
Schedule Change
NOTE: (Reports an E631, Exception Schedule Change; an E632, Access Schedule change.)
Once you have entered these report codes, the system prompts you with the Quit menu.
S
S
y
y
s
s
t
t
e
e
m
m
G
G
r
r
o
o
u
u
p
p
#
#
4
4
C
C
o
o
d
d
e
e
s
s
PROMPT EXPLANATION
SYSTEM GROUP #4 ?
1 = YES 0 = NO 0
To enter System Group #4 codes, press [1] (YES).
WALK TEST START
1st 00 2nd 00
Enter the first digit of the Walk Test Start Report Code (Sends an E607). Press []. Enter the second
digit of the report code.
Press [] to continue.
Enter the rest of the codes in the same manner. The other code in System Group #4 Walk-Test End
(Sends an R601).
Once you have entered these report codes, the system prompts you with the Quit menu.
KEYPAD LOCKOUT
1st 00 2nd 00
1
st
Digit: Enter a value other than 00
2
nd
Digit: Enter a value other than 00 (only if using a report format other than Contact ID).
QUIT MENU MODE?
1 = YES 0 = NO 0
Enter 1 to exit back to normal Programming mode. Enter 0 to stay in Menu mode.