SECTION 2: PROGRAMMING
Following is a list of commands used while in the Menu Mode:
#
#
9
9
3
3
M
M
e
e
n
n
u
u
M
M
o
o
d
d
e
e
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
C
C
o
o
m
m
m
m
a
a
n
n
d
d
s
s
#93 Enters Menu Mode.
[]
Serves as [ENTER] key. Press to have keypad accept entry and scroll forward.
[#] Backs up to previous screen.
0 Press to answer NO.
1 Press to answer YES.
00, or 000+[]
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu
option.
Z
Z
o
o
n
n
e
e
N
N
u
u
m
m
b
b
e
e
r
r
D
D
e
e
s
s
i
i
g
g
n
n
a
a
t
t
i
i
o
o
n
n
s
s
The VISTA-128BPT supports up to 128 zones, the
VISTA-250BPT supports up to 250 zones, of hardwire,
polling loop and/or wireless protection, distributed
among up to eight partitions. The following table lists
the zone numbers and the types of sensors that can be
used with each, and some alternate functions of the
zones.
Zone
Function
001
2-wire Smoke Detectors (if used)
005
Audio Alarm Verification (if used)
007
Keyswitch (if used)
001-009 Traditional Hardwired Zones
009 For unsupervised, N.C. use only.
001-250 5800 Series Wireless Devices
010-250 Polling Loop Devices
995
+ 1 Panic
996 # + 3 Panic
999
+ # Panic
Z
Z
o
o
n
n
e
e
D
D
e
e
f
f
a
a
u
u
l
l
t
t
s
s
Zone # Zone Type Zone # Zone Type
001
09
601-632
00
002
03
800-830
00
003
03
970
00
004**
04
988
00
005
03
990
00
006
03
992*
N/A
007
03
995
00
008
03
996
00
009
03
997
05
010250
00
999
06
NOTES:
* Zone 992 is the Duress zone. Programming of the zone
response type is not applicable. This zone requires only
the report code programming.
** Zone 004 is also defaulted with Auto-STAY enabled.
Z
Z
o
o
n
n
e
e
I
I
n
n
d
d
e
e
x
x
The zones are designated as follows:
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
001 250
Protection
zones
As indicated
601 632
Relay
Supervisory
Zones
6 + 2-digit Relay Number; e.g.,
Relay Number 03 is zone 603.
800 830 ECP Device
Supervisory
Zones
8 + 2-digit Device Address; e.g.,
Device Address 01 is zone 801.
970, 988,
990, & 997
System
Supervisory
Zones
970: Bell Supervision
988: 2nd Wireless Receiver
not receiving signals
990: 1st Wireless Receiver not
receiving signals
997: Polling Loop (short circuit)
992, 995
999
Duress and
Keypad
Panics
992: Duress
995: 1 + panic (A key)
996: 3 + # panic (C key)
999: + # panic (B key)
Program supervisory zones with response type of 05.
C
C
o
o
m
m
m
m
u
u
n
n
i
i
c
c
a
a
t
t
i
i
o
o
n
n
D
D
e
e
f
f
a
a
u
u
l
l
t
t
s
s
45 PRIMARY FORMAT [1] ADEMCO Contact ID
47 SECONDARY FORMAT [1] ADEMCO Contact ID
51 DUAL REPORTING [0] no