VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
FIELD TITLE and DATA ENTRIES Default Values
1
45
Exit Delay Sounding (partition-specific)
0 = disable
1 = enable
[1] A E
Enabled: T
he system produces slow beeping from the keypads during exit delay and reverts to rapid beeping during the
last 10 seconds of the exit delay.
NOTES: The duration of the beeping is the programmed value of field 10 regardless of which entry/exit zone is used
to exit the premises.
UL
MUST BE ENABLED (1) FOR A UL INSTALLATION.
See page 3-42, “SOUND OPTION”, prompt for disabling the entry/exit beeps on individual keypads.
1
46
Auxiliary Output Mode
0 = Not used
1 = Smoke detector reset
2 = Not used
3 = AAV module
[0] A E
Select the mode for output 1 on the J7 triggers.
Option 1 = Smoke Detector Reset (See Installation and Setup Guide Section 3)
Option 3 = AAV Module
Audio Alarm Verification (AAV) Module (also known as two-way voice), requires an add on module.
This feature is supported if Alarm reports are programmed to be sent to the primary phone number.
NOTE: Only one of the options may be active within the system.
1
47
Chime On Ext. Siren (partition-specific)
0 = disable
1 = enable
[0] A E
Enabled: Produces a ½ second burst on the bell output when a fault occurs on an entry/exit or perimeter zone.
1
48
Wireless Keypad Assignment
0 = none
1-8 = partition number
[0] A E
Select the partition in which RF keypad is used.
UL
WIRELESS KEYPAD IS NOT SUITABLE FOR USE IN A UL INSTALLATION
1
49
Suppress Transmitter Supervision Sound
0 = disable
1 = enable
[1] A E
Enabled: No trouble soundings occur on the keypad for transmitter check-in failures.
UL
MUST BE A 0 FOR A UL INSTALLATION
1
52
Send Cancel If Alarm + Off (partition-specific)
0 = disable
1 = enable
[1] A E
Enabled: Cancel reports are sent when the system is disarmed after an alarm, regardless of how much time has passed.
Disabled: Cancel reports are sent within Bell Timeout period only.
1
53
Disable Download Callback
0 = callback required
1 = no callback required
[0] A E
Select whether a callback from the control panel is required for downloading.
Enabled: No callback is required, panel answers according to the “Ring Detection Count” in location
44.
Disabled: The control senses the incoming call, panel answers, hangs up and calls the download number in 35.
UL
MUST BE A 0 FOR A UL INSTALLATION
1
55
International Date Format
0 = disable (mm/dd/yy)
1 = enable (dd/mm/yy)
[0] A E
Select the date format for display in the event log.