VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
Z
Z
o
o
n
n
e
e
L
L
i
i
s
s
t
t
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone
list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:
PROMPT EXPLANATION
ENTER Zn LIST ?
00=QUIT 00
Enter the zone list number 01-15. Enter 00 to quit.
01 ADD ZONE #
000=QUIT 000
Using 3-digit entries, enter each zone to be included in this zone list. Press [] after you enter each zone
number.
When you have entered all desired zones, enter 000.
Press [] to continue.
01 Del Zn LIST ?
1=YES 0=NO 0
Enter 0 to save this zone list.
Enter 1 to delete it. (000 in the first entry erases all zones in the list once saved when pressing [].
01 DEL ZONES ?
1=YES 0=NO 0
Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If you enter 1,
the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears.
01 Zn to DELETE ?
000=QUIT 000
Enter each zone number to be deleted from the zone list, pressing [] after each number.
VIEW Zn LIST ?
00=QUIT 00
This display appears if you pressed 00 at the “Enter Zone LIST” prompt. Enter the zone list number that
you wish to view.
Press [] to continue.
01 ASSIGNED ZONE
000=QUIT 000
Press [] to scroll through all zones in that list. Enter 000 + [] to quit.
Press 1 to exit Menu Mode.
Press 99 to exit Program Mode.