SECTION 4: SYSTEM LAYOUT WORKSHEETS
A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off; 4 =
Toggle alternately between START and STOP events
EV = EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble
ZL = ZONE LIST 01-15, 00 = Not Used
"START" ZONE LIST: Upon alarm, fault, trouble or restore of ANY zone in this list, device
action will START.
"STOP" ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It
need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00=zone not used 08=24-hour auxiliary 22=disarm
01=entry/exit 1 09=supervised fire 23=no alarm response
02=entry/exit 2
10=interior (delay)
26=Not Used
03=perimeter 12=Not Used 27=Not Used
04=interior (follower) 14=CO detector alarm 28=Not Used
05=day/night burglary 16=fire w/verification 29=momentary exit
06=24 hour silent 20=arm stay
07=24-hour audible
21=arm away
NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.
Any zone in "ZT" for Stop, that restores will stop the relay action.
Choices for System Operation are:
00 = No Response (Not Used)
27 = Access Point (allows more than
one relay to be controlled by
activation if access point
request)
42 = System Battery Low
01 = Entry/Exit #1
43 = Communication failure
02 = Entry/exit #2
44 = RF Low Battery
03 = Perimeter
45 = Polling Loop Failure
04 = Interior Follower
28 = MLB Supervision
47 = Console Failure
05 = Trouble Day/Alarm Night
29 = Momentary Exit
51 = RF Receiver Failure
06 = 24-Hr. Silent
31 = End of Exit Time
52 = Kissoff
07 = 24-Hr. Audible
32 = Start of Entry Time
54 = Fire Zone Reset
08 = 24-Hr. Auxiliary
33 = Any Burglary Alarm
55 = Disarm + 1 Minute
09 = Fire Alarm or Trouble
34 = Code + [#] + 71 Key Entry
56 = XX Minutes (enter XX in field
174) *
10 = Interior W/Delay
35 = Code + [#] + 72 Key Entry
16 = Fire With Verification
36 = At Bell Timeout **
57 = YY Seconds (enter YY in field
175) *
20 = Arming-STAY***
37 = 2 Times Bell Timeout **
21 = Arming-AWAY****
38 = Chime
58 = Duress
22 = Disarming (Code + Off)
39 = Fire Alarm
60 = Audio Alarm Verification (must be
selected for both START and
STOP operation)
23 = No Alarm Response
40 = Bypassing
41 = AC Power Fail
* Stop condition only
** Or at Disarming, whichever occurs earlier
*** The output also activates when the partition is armed in the INSTANT mode
**** The output also activates when the partition is armed in the MAXIMUM mode
P = PARTITION No. 1-8, 0 = Any
ZONE LISTS FOR OUTPUT DEVICESProgrammed in the #93 Menu Mode in the Output Programming Section. Fill in
the required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter
the data during the displays and prompts that appear in sequence. Up to 15 zone lists may be created
NOTE: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include
any or all of system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).