Registry Key Default Value Description
Configuration
IntelligentMailActivation 0x0
Enables the Intelligent Mail
symbology.
IntelligentMailCodeMark 0x2a
A single character inserted before
the bar code data to indicate the
symbology.
IntelligentMailUDSI "PA"
User-defined symbology identifier.
Range is 0-4 characters.
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Codabar] - Codabar Symbology Configuration
CodabarActivation 0x0 Enables the Codabar symbology.
CodabarCodeMark 0x44
A single character inserted before
the bar code data to indicate the
symbology.
CodabarCheckDigitVerification 0x0
Enables calculation of the check
digit.
CodabarBarCodeLengthL1 0x6
Length value L1. Range is 0x0 to
0xFF (0 to 255).
CodabarBarCodeLengthL2 0x0
Length value L2. Range is 0x0 to
0xFF (0 to 255).
CodabarBarCodeLengthL3 0x0
Length value L3. Range is 0x0 to
0xFF (0 to 255).
CodabarBarCodeLengthMode 0x0
Length verification mode, where 0
= "L1 is min length", 1 = "L1, L2, L3
are fixed lengths", and 2 = "L1 is
min, L2 is max length".
CodabarCheckDigitTransmission 0x0
Enable transmission of the check
digit.
CodabarStartStopTransmission 0x0
Selects start/stop character format
to transmit, where 0 = not
transmitted, 1 = "a, b, c, d", 2 = "A,
B, C, D", 3 = "a, b, c, d / t, n, *, e",
A700x Product Guide 80

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vocollect A700 Series and is the answer not in the manual?

Honeywell Vocollect A700 Series Specifications

General IconGeneral
BrandHoneywell
ModelVocollect A700 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals