Registry Key Default Value Description
and 4 = "DC1, DC2, DC3, DC4".
CodabarCLSILibrarySystem 0x0
Enables the CLSI (Computer
Library Services, Inc) library
standard for Codabar: 14
characters, no start/stop, spaces at
positions 2, 7, and 13.
CodabarConcatenation 0x0
Multiple label concatenation,
where 0 = disabled, 1 = only
concatenated, and 2 =
concatenate if possible.
CodabarConcatenationMode 0x0
Sets requirements for
concatenation, where 0 = no
requirements, 1 = Second code
start = first code stop, and 2 =
American Blood Commission
(second code start = first code stop
= 'd').
CodabarUDSI "B7"
User-defined symbology identifier.
Range is 0-4 characters.
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 93] - Code 93 Symbology Configuration
Code93Activation 0x0 Enables the Code 93 symbology.
Code93CodeMark 0x44
A single character inserted before
the bar code data to indicate the
symbology.
Code93BarCodeLengthL1 0x1
Length value L1. Range is 0x0 to
0xFF (0 to 255).
Code93BarCodeLengthL2 0x0
Length value L2. Range is 0x0 to
0xFF (0 to 255).
Code93BarCodeLengthL3 0x0
Length value L3. Range is 0x0 to
0xFF (0 to 255).
Code93BarCodeLengthMode 0x0
Length verification mode, where 0
= "L1 is min length", 1 = "L1, L2, L3
are fixed lengths", and 2 = "L1 is
81 A700x Product Guide