(Required.) Associating the Track module with a detection module:
Associating Track with NQA
Associating Track with BFD
Associating Track with CFD
Associating Track with interface management
Use one of the
methods.
(Required.) Associating the Track module with an application module:
Associating Track with VRRP
Associating Track with static routing
Associating Track with PBR
Associating Track with Smart Link
Use one of the
methods.
Associating the Track module with a detection
module
Associating Track with NQA
NQA supports multiple operation types to analyze network performance, services, and service quality.
For example, an NQA operation can periodically detect whether a destination is reachable, or whether
the TCP connection to a TCP server can be set up.
An NQA operation functions as follows when it is associated with a track entry:
If the consecutive failures reach the specified threshold, the NQA module notifies the Track module
that the tracked object has malfunctioned. Then the Track module sets the track entry to Negative
state.
If the specified threshold is not reached, the NQA module notifies the Track module that the tracked
object is functioning correctly. The Track module then sets the track entry to Positive state.
For more information about NQA, see Network Management and Monitoring Configuration Guide.
To associate Track with NQA:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Create a track entry,
associate it with an NQA
reaction entry, and specify the
delay time for the Track
module to notify the
associated application
module when the track entry
status changes.
track track-entry-number nqa entry
admin-name operation-tag reaction
item-number [ delay { negative
negative-time | positive
positive-time } * ]
No track entry is created by
default.
If the specified NQA operation or
the reaction entry in the track entry
does not exist, the status of the
track entry is NotReady.