[DeviceC-smlk-group1] flush enable control-vlan 10
[DeviceC-smlk-group1] quit
# Create smart link group 2, and configure all VLANs mapped to MSTI 2 as the protected VLANs
for smart link group 2.
[DeviceC] smart-link group 2
[DeviceC-smlk-group2] protected-vlan reference-instance 2
# Configure Ten-GigabitEthernet 1/0/1 as the secondary port and Ten-GigabitEthernet 1/0/2 as
the primary port for smart link group 2.
[DeviceC-smlk-group2] port ten-gigabitethernet 1/0/2 primary
[DeviceC-smlk-group2] port ten-gigabitethernet 1/0/1 secondary
# Enable role preemption in smart link group 2, enable flush message sending, and configure
VLAN 110 as the transmit control VLAN.
[DeviceC-smlk-group2] preemption mode role
[DeviceC-smlk-group2] flush enable control-vlan 110
[DeviceC-smlk-group2] quit
# Enable CFD and create MD MD_A of level 5.
[DeviceC] cfd enable
[DeviceC] cfd md MD_A level 5
# Create service instance 1 in which the MA name is based on the VLAN ID in MD_A and
configure the MA to serve VLAN 10.
[DeviceC] cfd service-instance 1 ma-id vlan-based md MD_A vlan 10
# Create a MEP list in service instance 1. Create outward-facing MEP 1001, and enable CCM
sending in service instance 1 on Ten-GigabitEthernet 1/0/1.
[DeviceC] cfd meplist 1001 1002 service-instance 1
[DeviceC] interface ten-gigabitethernet 1/0/1
[DeviceC-Ten-GigabitEthernet1/0/1] cfd mep 1001 service-instance 1 outbound
[DeviceC-Ten-GigabitEthernet1/0/1] cfd cc service-instance 1 mep 1001 enable
[DeviceC-Ten-GigabitEthernet1/0/1] quit
# Create service instance 2 in which the MA name is based on the VLAN ID in MD_A and
configure the MA to serve VLAN 110.
[DeviceC] cfd service-instance 2 ma-id vlan-based md MD_A vlan 110
# Create a MEP list in service instance 2. Create outward-facing MEP 2001. Enable CCM sending
in service instance 2 on Ten-GigabitEthernet 1/0/2.
[DeviceC] cfd meplist 2001 2002 service-instance 2
[DeviceC] interface ten-gigabitethernet 1/0/2
[DeviceC-Ten-GigabitEthernet1/0/2] cfd mep 2001 service-instance 2 outbound
[DeviceC-Ten-GigabitEthernet1/0/2] cfd cc service-instance 2 mep 2001 enable
[DeviceC-Ten-GigabitEthernet1/0/2] quit
# Create track entry 1 that is associated with the CFD CC function of MEP 1001 in service instance
1.
[DeviceC] track 1 cfd cc service-instance 1 mep 1001
# Configure the collaboration between the primary port Ten-GigabitEthernet 1/0/1 of smart link
group 1 and the CC function of CFD through track entry 1, and bring up the port.
[DeviceC] interface ten-gigabitethernet 1/0/1
[DeviceC-Ten-GigabitEthernet1/0/1] port smart-link group 1 track 1
[DeviceC-Ten-GigabitEthernet1/0/1] undo shutdown
[DeviceC-Ten-GigabitEthernet1/0/1] quit