Related commands
display port-security
port-security max-mac-count
port-security timer autolearn aging
Use port-security timer autolearn aging to set the secure MAC aging timer.
Use undo port-security timer autolearn aging to restore the default.
Syntax
port-security timer autolearn aging time-value
undo port-security timer autolearn aging
Default
Secure MAC addresses do not age out.
Views
System view
Predefined user roles
network-admin
Parameters
time-value: Sets the aging timer in minutes for secure MAC addresses. The value is in the range of 0 to
129600. To disable the aging timer, set the timer to 0.
Usage guidelines
The timer applies to all sticky secure MAC addresses and those automatically learned by a port.
A short aging time improves port access security and port resource utility but affects online user stability.
Set a proper secure MAC address aging timer according to your device performance and the network
environment.
Examples
# Set the secure MAC aging timer to 30 minutes.
<Sysname> system-view
[Sysname] port-security timer autolearn aging 30
Related commands
display port-security
port-security mac-address security
port-security timer disableport
Use port-security timer disableport to set the silence period during which the port remains disabled.
Use undo port-security timer disableport to restore the default.
132

Table of Contents

Other manuals for HP 5900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 and is the answer not in the manual?

HP 5900 Specifications

General IconGeneral
ModelHP 5900
Rack MountableYes
MAC Address Table Size128K
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, IS-IS, IGMP
Remote Management ProtocolSNMP, CLI
FeaturesQuality of Service (QoS), Jumbo Frames support, IPv4 support, IPv6 support
Operating Temperature0 °C to 45 °C
Operating Humidity10% to 90% non-condensing
Power SupplyInternal power supply - hot-plug / redundant

Related product manuals