Parameters
minutes: Real-time accounting interval in minutes, in the range of 0 to 60. Setting this interval to 0
disables the device from sending online user accounting information to the HWTACACS accounting
server.
Usage guidelines
For real-time accounting, a NAS must transmit the accounting information of online users to the
HWTACACS accounting server periodically. This command is used to set the interval.
Different real-time accounting intervals impose different performance requirements on the device and the
HWTACACS server. A shorter interval helps achieve higher accounting precision but requires higher
performance. Use a longer interval when there are a large number of users (1000 or more).
Table 8 Recommended real-time accounting intervals
Number of users
Real-time accountin
g
interval
1 to 99 3 minutes
100 to 499 6 minutes
500 to 999 12 minutes
1000 or more 15 minutes or longer
Examples
# Set the real-time accounting interval to 51 minutes for HWTACACS scheme hwt1.
<Sysname> system-view
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] timer realtime-accounting 51
Related commands
display hwtacacs scheme
timer response-timeout (HWTACACS scheme view)
Use timer response-timeout to set the HWTACACS server response timeout timer.
Use undo timer response-timeout to restore the default.
Syntax
timer response-timeout seconds
undo timer response-timeout
Default
The HWTACACS server response timeout time is 5 seconds.
Views
HWTACACS scheme view
78

Table of Contents

Other manuals for HP 5900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5900 and is the answer not in the manual?

HP 5900 Specifications

General IconGeneral
ModelHP 5900
Rack MountableYes
MAC Address Table Size128K
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, IS-IS, IGMP
Remote Management ProtocolSNMP, CLI
FeaturesQuality of Service (QoS), Jumbo Frames support, IPv4 support, IPv6 support
Operating Temperature0 °C to 45 °C
Operating Humidity10% to 90% non-condensing
Power SupplyInternal power supply - hot-plug / redundant

Related product manuals