226
View
System view
Default level
2: System level
Parameter
count: Sets the number of the LLDPDUs sent each time fast LLDPDU transmission is triggered. The
parameter ranges from 1 to 10.
Example
# Configure the device to send four LLDPDUs each time fast LLDPDU transmission is triggered.
<Sysname> system-view
[Sysname] lldp fast-count 4
lldp hold-multiplier
Description
Use the lldp hold-multiplier command to set the TTL multiplier.
Use the undo lldp hold-multiplier command to restore the default.
By default, the TTL multiplier is 4.
You can set the TTL of the local device information by configuring the TTL multiplier.
The TTL configuration of a device is determined by the following expression:
TTL multiplier × LLDPDU transmit interval
The TTL can be up to 65,535 seconds. Longer TTLs will be rounded off to 65,535 seconds.
Related commands: lldp timer tx-interval.
Syntax
lldp hold-multiplier value
undo lldp hold-multiplier
View
System view
Default level
2: System level
Parameter
value: Sets the TTL multiplier, ranging from 2 to 10.
Example
# Set the TTL multiplier to 6.
<Sysname> system-view
[Sysname] lldp hold-multiplier 6