Default level
2: System level
Parameters
aging seconds: Sets an aging timer (in seconds) for dynamic MAC address entries. The value is in the
range of 10 to 1,000,000 seconds.
no-aging: Sets dynamic MAC address entries not to age.
Example
# Set the aging timer for dynamic MAC address entries to 500 seconds.
<Sysname> system-view
[Sysname] mac-address timer aging 500