8-5
Configuring IP Addressing
IP Configuration
The IP addressing used in the switch should be compatible with your
network. That is, the IP address must be unique and the subnet mask must
be appropriate for your IP network.
If you change the IP address through either Telnet access or the web
browser interface, the connection to the switch will be lost. You can
reconnect by either restarting Telnet with the new IP address or entering
the new address as the URL in your web browser.
IP Addressing in a Stacking Environment
If you are installing the switch into an ProCurve stack management environ-
ment, entering an IP address may not be required. See the chapter on stack
management in the Advanced Traffic Management Guide.
Menu: Configuring IP Address, Gateway, and Time-To-
Live (TTL)
Do one of the following:
To manually enter an IP address, subnet mask, set the IP Config parameter
to Manual and then manually enter the IP address and subnet mask values
you want for the switch.
To use DHCP or Bootp, use the menu interface to ensure that the IP Config
parameter is set to DHCP/Bootp, then refer to “DHCP/Bootp Operation” on
page 8-12.
To Configure IP Addressing.
1. From the Main Menu, Select.
2. Switch Configuration ...
5. IP Configuration
Note If multiple VLANs are configured, a screen showing all VLANs appears instead
of the following screen.

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm

Related product manuals