EasyManuals Logo

HP ProCurve 2510-24 User Manual

HP ProCurve 2510-24
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
4-4
Using the Command Line Interface (CLI)
Using the CLI
Caution ProCurve strongly recommends that you configure a Manager password. If
a Manager password is not configured, then the Manager level is not password-
protected, and anyone having in-band or out-of-band access to the switch may
be able to reach the Manager level and compromise switch and network
security. Note that configuring only an Operator password does not prevent
access to the Manager level by intruders who have the Operator password.
Pressing the Clear button on the front of the switch removes password
protection. For this reason, it is recommended that you protect the switch
from physical access by unauthorized persons. If you are concerned about
switch security and operation, you should install the switch in a secure
location, such as a locked wiring closet.
Privilege Level Operation
Figure 4-2. Access Sequence for Privilege Levels
Operator Privileges
At the Operator level you can examine the current configuration and move
between interfaces without being able to change the configuration. A ">"
character delimits the Operator-level prompt. For example:
ProCurve> _ Example of the Operator prompt.
When using enable to move to the Manager level, the switch prompts you for
the Manager password if one has already been configured.
2. Manager Level
3. Global Configuration
Operator Privileges
Manager Privileges
1. Operator Level
4. Context Configuration Level

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm