Troubleshooting
Using Logging To Identify Problem Sources
Enabling or Disabling Logging to Management Sessions and SyslogD
Servers. Use this command when you want to do any of the following:
Disable Syslog logging on all currently configured SyslogD servers with-
out removing the servers from the switch configuration.
Re-enable Syslog logging if it is disabled and there is at least one SyslogD
server currently configured in the switch.
Enable or disable logging output to the current management-access ses-
sion.
For example, figure C-11 shows the process for checking the current Syslog
status and then disabling Syslog logging.
Syntax: [no] debug destination < logging | session >
logging
The no form of the command disables Syslog logging,
but retains the currently configured SyslogD server
addresses in the switch configuration.When Syslog log-
ging is currently disabled with one or more SyslogD
servers configured, this command enables Syslog log-
ging on the switch. The show config command output
includes the SyslogD server IP addresses currently con-
figured in the startup-config file.
session
Enables and disables debug logging to the current ses-
sion. The “current session” is the session that most
recently executed debug destination session on the switch
(since the last reboot). This makes it easy to move
session logging from one session to another.

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm