181
Server specifications
In this section
Environmental specifications .....................................................................................................181
Server specifications...................................................................................................................181
Environmental specifications
Temperature range* Specification
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Specification
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Dimension Specification
Height 17.6 cm (6.94 in)
Depth 67.3 cm (26.5 in)
Width 46.3 cm (19.0 in)
Weight (maximum) 47.6 kg (105 lb)