HP Smart Array errors  117 
Severity: Warning 
Log message: The recovery of logical drive <logical drive number> configured on 
array controller <controller name / slot information> was aborted while 
rebuilding due to an unrecoverable write error. Physical drive number <physical 
drive number> was the replacement drive being rebuilt before the write error 
occurred, while physical drive number <physical drive number> is the error drive 
which reported the write error. 
Message Id: 24605 
Severity: Warning 
Log message: Due to an unrecoverable write error, the recovery of logical drive 
<logical drive number> configured on array controller <controller name / slot 
information> was aborted while rebuilding a physical drive. 
The physical drive which was being rebuilt is located in bay <bay number> of box 
<box number> which is connected to port <port number> of array controller 
<controller name / slot information>. 
The physical drive that reported the write error is located in bay <bay number> 
of box <box number> which is connected to port <port number> of array controller 
<controller name / slot information>. 
Message Id: 24606 
Severity: Error 
Log message: Logical drive <logical drive number> configured on array controller 
<controller name / slot information> returned a fatal error during a read/write 
request from/to the volume. 
Logical block address <lba number>, block count <bc number> and command <command 
number> were taken from the failed logical I/O request. 
Array controller <controller name / slot information> is also reporting that the 
last physical drive to report a fatal error condition (associated with this 
logical request), is located on bus <bus number> and ID <ID number>. 
Message Id: 24607 
Severity: Warning 
Log message: The event information received from array controller <controller name 
/ slot information> was of an unknown or unrecognized class. 
An excerpt of the controller message is as follows: <message from firmware>. 
Message Id: 24608 
Severity: Informational 
Log message: Array controller <controller name / slot information> has reported that 
storage box number <box number> was added to port <port number>. This connection 
is through I/O module number <module number> on the storage box. 
Message Id: 24609 
Severity: Error 
Log message: Array controller <controller name / slot information> has reported that 
storage box number <box number> was removed from port <port number>. This 
connection was through I/O module number <module number> on the storage box. This 
event can occur when either a sole I/O module or data cable is removed.