HP Smart Array errors 117
Severity: Warning
Log message: The recovery of logical drive <logical drive number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable write error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the write error
occurred, while physical drive number <physical drive number> is the error drive
which reported the write error.
Message Id: 24605
Severity: Warning
Log message: Due to an unrecoverable write error, the recovery of logical drive
<logical drive number> configured on array controller <controller name / slot
information> was aborted while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the write error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24606
Severity: Error
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> returned a fatal error during a read/write
request from/to the volume.
Logical block address <lba number>, block count <bc number> and command <command
number> were taken from the failed logical I/O request.
Array controller <controller name / slot information> is also reporting that the
last physical drive to report a fatal error condition (associated with this
logical request), is located on bus <bus number> and ID <ID number>.
Message Id: 24607
Severity: Warning
Log message: The event information received from array controller <controller name
/ slot information> was of an unknown or unrecognized class.
An excerpt of the controller message is as follows: <message from firmware>.
Message Id: 24608
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
storage box number <box number> was added to port <port number>. This connection
is through I/O module number <module number> on the storage box.
Message Id: 24609
Severity: Error
Log message: Array controller <controller name / slot information> has reported that
storage box number <box number> was removed from port <port number>. This
connection was through I/O module number <module number> on the storage box. This
event can occur when either a sole I/O module or data cable is removed.