HP Smart Array errors 135
• PHY_RESET_FAILED - Phy reset request failed.
• FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
• FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
• OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
• OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that
is too small.
• OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
• OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation
has completed on it but it hasn’t been replaced yet.
Message Id: 24710
Severity: Informational
Log message:
The external Smart Array controller located in the MSA chassis labeled as <chassis
label> has reported that logical drive <logical drive number> has encountered
a status change from:
Status: <previous status>
to
Status: <current status>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<previous status> and <current status> values:
• “OK”
• “FAILED”
• “NOT CONFIGURED”
• “INTERIM RECOVERY MODE”
• “READY FOR RECOVERY”
• “RECOVERING”
• “WRONG PHYSICAL DRIVE REPLACED”
• “PHYSICAL DRIVE NOT PROPERLY CONNECTED”
• “HARDWARE IS OVERHEATING”
• “HARDWARE HAS OVERHEATED”
• “EXPANDING”
• “NOT YET AVAILABLE”
• “QUEUED FOR EXPANSION”
• “DISABLED DUE TO SCSI ID CONFLICT”
• “EJECTED”