HP Smart Array errors 138
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24715
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that due to an unrecoverable read error, the
recovery of logical drive <logical drive number> was aborted while rebuilding
a physical drive. The physical drive which was being rebuilt is located in bay
<bay number 1> of the MSA chassis. The physical drive that reported the read error
is located in bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24716
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the recovery of logical drive <logical drive
number> was aborted while rebuilding due to an unrecoverable write error. Physical
drive number <physical drive number 1> was the replacement drive being rebuilt
before the write error occurred, while physical drive number <physical drive
number 2> is the error drive which reported the write error.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24717
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that due to an unrecoverable write error, the
recovery of logical drive <logical drive number> was aborted while rebuilding
a physical drive. The physical drive which was being rebuilt is located in bay
<bay number 1> of the MSA chassis. The physical drive that reported the write
error is located in bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24718
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that logical drive <logical drive number> returned
a fatal error during a read/write request from/to the volume.
Logical block address <lba number>, block count <block count> and command <command
number> were taken from the failed logical I/O request.
The external Smart Array controller is also reporting that the last physical drive
to report a fatal error condition(associated with this specific logical request),
is located on bus <bus number> and ID <ID number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24719
Severity: Warning