HP Smart Array errors 137
to
Status: <previous status>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<previous status> and <current status> values:
OK
FAILED
NOT CONFIGURED
INTERIM RECOVERY MODE
READY FOR RECOVERY
RECOVERING
WRONG PHYSICAL DRIVE REPLACED
PHYSICAL DRIVE NOT PROPERLY CONNECTED
HARDWARE IS OVERHEATING
HARDWARE HAS OVERHEATED
EXPANDING
NOT YET AVAILABLE
QUEUED FOR EXPANSION
DISABLED DUE TO SCSI ID CONFLICT
EJECTED
ERASING
UNKNOWN
Message Id: 24713
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that logical drive <logical drive number> is in
a failed state but has had one or more drive replacements and is now ready to
change to a status of "OK". However, this status change will not occur until
the logical drive is re-enabled. Please re-enable the logical drive either via
the HP Array Configuration Utility or by power cycling the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24714
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the recovery of logical drive <logical drive
number> was aborted while rebuilding due to an unrecoverable read error. Physical
drive number <physical drive number 1> was the replacement drive being rebuilt
before the read error occurred, while physical drive number <physical drive number
2> is the error drive which reported the read error.

Table of Contents