HP Smart Array errors 146
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that redundant path number <path number> for the
<drive type> physical drive located in bay <bay number> has either failed or been
removed.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24759
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached between port <port number> and box
<box number>. <firmware information>. Please check the cabling and ensure that
a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24760
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached to port <port number>. <firmware
information>. Please check the cabling and ensure that a supported configuration
is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24761
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an unsupported configuration has occurred
with the redundant cabling that is attached to port <port number>. Please check
the cabling and ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24762
Severity: Informational
Log message:
External Smart Array controller number <controller number> located in the MSA
chassis labeled as <chassis label> is reporting the following flash operation:
"<firmware message>."
The firmware was flashed from:
Revision: <old revision number>
to
Revision: <new revision number>

Table of Contents