EasyManua.ls Logo

HP ProLiant Gen9 - Page 151

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP Smart Array errors 151
GDP_VPD_INQUIRY_FAILED - Could not read drive serial number after multiple
retries.
GDP_MODE_SENSE_FAILED - Could not read certain mode pages after multiple
retries.
DRIVE_NOT_IN_48BIT_MODE - SATA drive is not supported in 48-bit LBA mode.
DRIVE_TYPE_MIX_IN_HOT_PLUG - Attempt to hot-add a SATA drive as a replacement
in a SAS-only volume, or vice versa.
DRIVE_TYPE_MIX_IN_LOAD_CFG - attempt to use a SATA drive as a replacement
in a SAS-only volume, or vice versa.
PROTOCOL_ADAPTER_FAILED - Protocol layer reports that the protocol hardware
has failed; may be a controller failure.
FAULTY_ID_BAY_EMPTY - Drive responds to SCSI ID, but the corresponding bay
is empty.
FAULTY_ID_BAY_OCCUPIED - Bay is occupied by a drive that does not respond
to the corresponding SCSI ID.
FAULTY_ID_INVALID_BAY - Drive responds to an ID that doesn’t have a valid
corresponding bay.
WRITE_RETRIES_FAILED - Unable to complete a write operation after several
retries.
QUEUE_FULL_ON_ZERO - Drive indicates that its queue is full when we have no
requests outstanding to the drive.
SMART_ERROR_REPORTED - Drive has reported a predictive-failure error when
controller is configured to automatically fail [instead of reporting imminent
failure of] drives that report this error.
PHY_RESET_FAILED - Phy reset request failed.
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that
is too small.
OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation
has completed on it but it hasn’t been replaced yet.
Message Id: 24776
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive located
in bay <bay number> is now online.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.

Table of Contents

Related product manuals