HP Smart Array errors 152
Message Id: 24777
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting inconsistent data that was previously
consistent.<additional information>The inconsistent data may be caused by a power
loss during write activity or by a drive returning corrupt data. The inconsistent
data is between block address <lba number 1> and block address <lba number 2>
of logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<additional information> values:
The parity data does not match the data drives.
“”
Message Id: 24778
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that surface analysis has repaired an inconsistent
stripe on logical drive <logical drive number> by overwriting the statistically
incorrect stripe on the physical drive found in bay <bay number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24779
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that surface analysis has repaired an inconsistent
stripe on logical drive <logical drive number> by updating the parity data to
match the data drive contents.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24780
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting inconsistent data that was previously
consistent.<additional information>The inconsistent data may be caused by a power
loss during write activity or by a drive returning corrupt data. The inconsistent
data is between block address <lba number 1> and block address <lba number 2>
of logical drive <logical drive number>. The physical drive containing the
inconsistent data can be found in bay <bay number> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<additional information> values:
The parity data does not match the data drives.
“”
Message Id: 24781