EasyManua.ls Logo

HP ProLiant Gen9 - Page 153

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP Smart Array errors 153
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <module number> was <inserted
/ removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24782
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> has failed.
The external Smart Array controller may attempt to shut down power and/or spin
down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24783
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> is reporting
a degraded condition.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24784
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan module <fan module number> is now
operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id=24785
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a previously failed storage enclosure
processor (SEP) is now responding and operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24786
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a storage enclosure processor (SEP) has
failed.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24787

Table of Contents

Related product manuals