HP Smart Array errors 154
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that all storage enclosure processors (SEPs) have
failed and there is currently no environmental management and monitoring
available for this storage enclosure.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24788
Severity: Informational
Log message: Surface analysis parity/consistency initialization forced complete
for logical drive <logical drive number> on external Smart Array array controller
located in the MSA chassis labeled as <chassis label>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24789
Severity: Informational
Log message: External Smart Array controller located in the MSA chassis labeled as
<chassis label> has reported that <number of passes> surface analysis passes have
completed for logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24790
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> is reporting that the <drive type> physical drive located
in bay <bay number> is in a SMART trip state that indicates the drive has reached
0 percent usage left. Indicates that the drive has a S.M.A.R.T wear error and
is approaching the maximum usage limit for writes (wear out). The drive should
be replaced as soon as possible.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id=24791
Severity: Error
Log message: Array controller <controller name / slot information> has reported that
its internal temperature has exceeded the preset limit of <temperature limit>°C.
The current temperature is <current temperature>°C as reported by sensor number
<sensor number>. The controller may attempt to shut down power and/or spin down
installed disk drives.
Message Id: 24792
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that
its internal temperature is nearing the preset temperature limit of <temperature
limit>°C. The current temperature is <current temperature>°C as reported by
sensor number <sensor number>. The array controller may enact precautionary
measures to prevent data loss should the temperature reach the operating limit.