HP ProLiant server errors 72
• If this error persists, replace the cache module and controller.
1703 - Slot X Drive Array controller - Memory Self-Test Error - Access to all storage
has been disabled...
...Access to all storage has been disabled. Replace the Array Accelerator daughtercard if this error persists after
restarting system.
Audible Beeps: None
Possible Cause: The cache module has failed or is experiencing a fault.
Action: Replace the cache module.
1704-Unsupported Virtual Mode Disk Operation - System Halted
Audible Beeps: None
Possible Cause: The operating system currently running does not support virtual DMA service.
Action: Load or update the device driver appropriate for the operating system.
1706-The Extended BIOS Data Area in Server Memory has been Overwritten...
...Smart Array Interrupt 13h BIOS Cannot Continue - System Halted
Audible Beeps: None
Possible Cause: An application has overwritten memory reserved by the Smart Array controller.
Action: If this occurs when a particular application is loaded, check for an updated version of that
application.
1707-Slot X Drive Array Controller - Bootstrap NVRAM checksum failed
The second line of the message includes one of the following lines of text:
(unrecoverable error)
or
(no suitable backup found)
Audible Beeps: None
Possible Cause: The Bootstrap NVRAM on the specified Smart Array controller is corrupt or invalid.
Action:
1. Update the controller with the latest firmware version.
2. If the problem still exists, replace the controller.
1708-Slot X Drive Array Controller - Bootstrap NVRAM restored from backup. System
restart required
Audible Beeps: None
Possible Cause: The specified Smart Array controller Bootstrap NVRAM was restored in one of the following
ways:
• It was detected as corrupt, and the backup copy was restored.