HP ProLiant server errors 73
It was automatically updated because a newer version was available.
Action:
1. Reboot the server.
2. If the problem still exists, update the controller to the latest firmware version.
1710-Slot X Drive Array - Non-Array Controller Drives Detected Warning: possible
data loss may occur...
...Physical drive(s) detected which had been previously attached to a non-array controller. Any non-array data on
these drives will be lost unless they are removed. To save data, turn off system power immediately and remove the
drives.
Audible Beeps: None
Possible Cause: One or more physical drives were attached to a non-array controller.
Action: Power down the system, and then remove the drives.
1711-Slot X Drive Array - Stripe size too large for RAID 5/6 logical drive(s)
...This configuration is not recommended due to transfer buffer usage. Consider migrating to smaller stripe size via
Array Configuration Utility.
Possible Cause: This configuration is not recommended because of controller memory requirements.
Action: Perform RAID migration to smaller stripe size using HP SSA.
1713-Slot X Drive Array - Redundant ROM Reprogramming Failure...
...Replace the controller if this error persists after restarting system.
Audible Beeps: None
Possible Cause: Flash ROM is failing. The controller detects a checksum failure, but is unable to reprogram
the backup ROM.
Action:
1. Update the controller to the latest firmware version.
2. If the problem persists, replace the controller.
1714-Slot X Drive Array - Redundant Checksum Error...
...Backup ROM has automatically been activated; check firmware version.
Audible Beeps: None
Possible Cause: The controller flash operation is interrupted by a power cycle, or flash ROM is failing. The
controller detects a ROM checksum error and automatically switches to the backup ROM image.
Action: If this backup ROM image is a lower version than the originally running image, update the controller
to the latest firmware version.
1715-Slot X Drive Array Controller - Memory Error(s) Occurred...
Warning: Corrected Memory Error(s) were detected during controller memory self-test. Upgrade to the latest firmware.
If the problem persists, replace the Cache Module or Controller.