HP ProLiant server errors 74
Possible Cause: The memory is beginning to fail.
Action:
Upgrade to the latest firmware.
If this error persists, replace the cache module and controller.
1716-Slot X Drive Array - Unrecoverable Media Errors Detected on Drives during
previous Rebuild or Background Surface Analysis scan...
...Errors will be fixed automatically when the sector(s) are overwritten. Backup and restore recommended.
Audible Beeps: None
Possible Cause: A media error is detected on a drive and cannot be corrected because of degraded fault
tolerance or a media error at the same location on another drive in the same array. An unrecoverable read
error is returned to the operating system when this block address is read.
Action: Backup and restore the data on the drive. Sequential write operations to the affected blocks should
resolve the media errors.
1717-Slot X Drive Array - Disk Drive(s) Reporting OVERHEATED Condition: Port X
Box Y Bay(s) Z
Audible Beeps: None
Possible Cause: The drives listed in this message are currently in an overheated state.
Action: Check the fans and be sure the air flows over the drive. Install the access panel, if removed.
1718-Slot X Drive Array - Device discovery found more devices attached to this
controller than firmware currently supports...
...Some devices are ignored.
Audible Beeps: None
Possible Cause: The firmware does not support the number of devices currently attached to the controller.
Action:
If release notes indicate that support for additional devices has been added, upgrade to the latest
version of controller firmware.
Remove some of the devices attached to the controller.
1719-Slot X Drive Array - A controller failure event occurred prior to this power-up
(previous lock-up code = 0x####)
Audible Beeps: None
Possible Cause: A controller failure event occurred before the server powered up.
Action: Install the latest version of controller firmware. If the condition persists, then replace the controller.