Table 8-2 Robot environmental specifications
Type Value
Relative humidity range when operating 20–80%
Temperature range when operating Solvent-based inks: −10 to +40°C (14 to 104°F)
Water-based inks: 0 to +40°C (32 to 104°F)
Temperature range when in storage −20 to +55°C (−4 to +131°F)
Temperature gradient no more than 10°C/h (18°F/h)
Maximum altitude when operating 2000 m (6600 ft)
Surface condition when operating Dry
Storage conditions Indoor
Battery charging Indoor
Temperature range when charging battery 0 to 40°C (32 to 104°F)
NOTE: If the robot or ink cartridges are moved from a cold location to a warm and humid location,
water from the atmosphere can condense on the robot parts and cartridges and can result in ink leaks
and robot errors. In this case, HP recommends that you wait at least 3 hours before turning on the robot
or installing the ink cartridges, to allow the condensation to evaporate.
Acoustic specifications
Declared noise emission levels for the HP SitePrint Robot.
Sound pressure levels measured according to ISO 11201 and sound power levels measured according to
ISO 3744.
Table 8-3
Acoustic specifications
Characteristic Status Specifications
Sound pressure Printing (lines) 55 dB(A)
Standby 40 dB(A)
Sound power Printing (lines) ≤ 7.0 B(A)
Standby ≤ 5.5 B(A)
Radio specifications
Characteristics of the robot’s radio communications.
Table 8-4
Radio specifications
Characteristic Specifications
WiFi Wi-Fi 6 (802.11ax)
Bluetooth Bluetooth 5.2