Some subsystem and device types, such as the Agentless Management Service, do not have a related page.
Redundancy status
Redundancy status is displayed for the following:
• Fan Redundancy
• Power
Subsystem and device status
Summarized status information is displayed for the following:
• Agentless Management Service
• BIOS/Hardware Health
• Fans
• Memory
•
Network
•
Processors
•
Storage
•
Temperatures
• Smart Storage Energy Pack (supported servers only)
Subsystem and device status values
• Redundant—There is a backup component for the device or subsystem.
• OK—The device or subsystem is working correctly.
•
Not Redundant—There is no backup component for the device or subsystem.
• Not Available—The component is not available or not installed.
• Degraded—The device or subsystem is operating at a reduced capacity.
iLO displays the power supply status as Degraded when mismatched power supplies are installed.
If you power on a server with nonredundant fans or power supplies, the system health status is listed as OK. If a redundant
fan or power supply fails while the system is powered on, the system health status is Degraded until you replace the fan or
power supply.
•
Failed Redundant—The device or subsystem is in a nonoperational state.
•
Failed—One or more components of the device or subsystem are nonoperational.
• Other—For more information, navigate to the System Information page of the component that is reporting this status.
74 Using HPE iLO 5