Some subsystem and device types, such as the Agentless Management Service, do not have a related page.
Redundancy status
Redundancy status is displayed for the following:
Fan Redundancy
Power
Subsystem and device status
Summarized status information is displayed for the following:
Agentless Management Service
BIOS/Hardware Health
Fans
Memory
Network
Processors
Storage
Temperatures
Smart Storage Energy Pack (supported servers only)
Subsystem and device status values
Redundant—There is a backup component for the device or subsystem.
OK—The device or subsystem is working correctly.
Not Redundant—There is no backup component for the device or subsystem.
Not Available—The component is not available or not installed.
Degraded—The device or subsystem is operating at a reduced capacity.
iLO displays the power supply status as Degraded when mismatched power supplies are installed.
If you power on a server with nonredundant fans or power supplies, the system health status is listed as OK. If a redundant
fan or power supply fails while the system is powered on, the system health status is Degraded until you replace the fan or
power supply.
Failed Redundant—The device or subsystem is in a nonoperational state.
Failed—One or more components of the device or subsystem are nonoperational.
Other—For more information, navigate to the System Information page of the component that is reporting this status.