Specifications
Environmental specifications
Table 1: Standard specifications
Specification Value
Temperature range
1
—
Operating 0°C to 55°C (32°F to 131°F)
2
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating 8% to 90% at 28°C (824°F) maximum wet bulb temperature
Non-Operating 5% to 95% at 387°C (1017°F) maximum wet bulb
temperature
1
All temperature ratings shown are for sea level. An altitude derating of
10°C per 3048 m (18°F per 1000 ft) to 3048 m (10000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). No restrictions on product configurations.
Not rated for operation over 3048 m (10000 ft).
2
Fan failure might reduce performance.
Table 2: ASHRAE Class A4 specifications
Specification
Value
Temperature range
1
—
Operating 0°C to 45°C (32°F to 113°F)
10°C to 35°C (50°F to 95°F) when GPU is installed
2
Nonoperating -10°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating 8% to 90% at 28°C (824°F ) maximum wet bulb temperature
Non-Operating 5% to 95% at 387°C (1017°F) maximum wet bulb
temperature
1
All temperature ratings shown are for sea level. An altitude derating of
10°C per 125 m (18°F per 410 ft) to 900 m (2953 ft) is applicable.
No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). No restrictions on product configurations except for
rotating hard drives. PCI cards must be rated for continuous operation with 60°C cooling air. Not rated for operation over 3048 m (10000
ft).
2
Fan failure might reduce performance.
Specifications 173