3. Slide the server into the rack.
4. Connect all peripheral cables to the server.
5.
Connect the power cords:
a.
Connect each power cord to the server.
b.
Connect each power cord to the power source.
6.
Power up the server.
The installation is complete.
Installing the PCI fan and air bale options
The PCI fan option is required to meet the system thermal requirement when any of the following expansion board
options are installed:
Type-p Smart Array controllers
High-performance NIC controllers
10 GB Ethernet adapters
GPUs
M.2 SSDs
Third-party expansion boards
NOTE: A PCI fan is also required while the server is in rack mode.
CAUTION: For proper cooling, do not operate the server without the access panel, bales, expansion slot covers, or
blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Hardware options installation 47