Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
• If the server is in tower mode:
Position the tower server for hardware configuration.
• If the server is in rack mode: Remove the server from the rack.
5.
Remove the front bezel.
6. Remove the access panel.
7. If installed,
remove the air bale.
8.
Install the M.2 SSD/dedicated iLO/serial port enablement board.
9.
Identify the appropriate stando position and install the hex nut.
10. Install the M.2 SSD:
a. Insert the SSD into the M.2 slot at a 45° angle.
b. Carefully press the SSD down to the horizontal position.
c. Install the SSD mounting screw.
80
Hardware options installation