Chapter 7 Detailed Function Introduction Shenzhen Hpmont Technology Co., Ltd.
- 34 - HD09-S Series User Manual V1.1
7.3 F01: Parameter Protection Function
Ref. Code Function Description Setting Range [Default]
F01.00 User password 00000 - 65535 [00000]
XXXXX: After user password setted (not all zero), password will be valid. Only function parameter can be
viewed via keypad.
If needing to change parameter, right password shall be entered.
00000: Setted at 00000, the password is not valid and if password has been existed before, then it will be
removed.
Password setting: After setting, press button / back to stop / running status or no action for 5
minustes, the password will be valid.
F01.01 Menu mode selection 0,1 [0]
0: Standard menu mode.
Display all parameter.
1: Verifying menu mode.
Only display parameters different from default setting.
F01.02 Function code parameter initialization (parameter download) 0 - 6 [0]
0: No action.
The inverter is in normal status of parameter reading and writing.
Whether the parameters can be changed, depends on the setting status
of the user password and the current working condition of the inverter.
1: Restore the factory parameter.
Except F01.00, F01.02, F01.03, F08, F13.01 - F13.15, F19.15, F19.19, F19.24,
F20.08, F20.09, F20.21 - F20. 37, F23.00 and group y.
Operation steps: Set F01.02 = 1, press key confirm. At this
moment, the factory parameters are restored. The "rESEt" is displayed on
the keypad. After the factory parameters are restored, the keypad displays
the parameters of stop status.
2: Cope the storaged parameter 1 of keypad to controller board for current function code value updating.
3: Cope the storaged parameter 2 of keypad to controller board for current function code value updating.
4: Clear out fault records.
Clear out the recorded fault information in F20.21 - F20.37.
5: Keypad storage parameters 1 is copied to the control keypad and update the current function code setting
(including motor parameters).
6: keypad storage parameter 2 is copied to the control keypad and the current function code setting value
(including motor parameters) is updated.
Note:
1. The parameters F01.00, F01.02, F01.03, F20.21 - F20.37 and y are not copied.
2. Options 2, 3, 5, 6 are only valid when the operator keypad is used externally.
F0
1.
02 = 2 / 3 / 5 / 6
Inver
ter
K
ey
pa
d
D
ownl
oa
d
K
ey
pa
d st
ored
fu
nct
io
n p
ar
am
ete
r

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD09-S Series and is the answer not in the manual?

hpmont HD09-S Series Specifications

General IconGeneral
Brandhpmont
ModelHD09-S Series
CategoryInverter
LanguageEnglish

Related product manuals