EasyManua.ls Logo

HTC 2500 iX - Appendix 1 - Additions to Manual for HTC 2500 IX

HTC 2500 iX
391 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
Appendix 1 – Additions to manual for HTC 2500 iX
A freight container is recommended for transporting the ma-
chine. When anchoring the machine, the following methods
are recommended:
Securing strap or chain in the towing eyelets at the front,
under the mountings for the grinding heads, and under the
loading platform at the rear.
Chocks in front of & behind the pairs of wheels.
Securing strap around the wheels with mounting points in
the oor.
The ramp for the container may not exceed an incline of 10°.
Lifting points for the machine are located directly in front of
the pairs of wheels.
When lifting with a crane, stays must be positioned under
the lifting points.
Wheel replacement
When replacing wheels, position the jack at the lifting point
by the wheel that is to be replaced.
Mist cooler system
You are recommended to use decalcied water for the Mist
cooler system.
When storing the machine, drain the water tank for the Mist
cooler system.
Maintenance instructions
Fill with diesel & water.
Ensure that the machine is turned off.
Transportation of the machine The engine must not be in operation and the electrical system must
be disconnected.
Remove the cover and top up the tank.
Do not use category 2 & 3 diesel. This would reduce the engine’s
service life and result in the particle lter having to be cleaned at
more regular intervals.
Service and maintenance – General overview
Check the absolute lter for the vacuum cleaning system. If it
is dusty, check the sock lters for leaks. See page 21, point 4.
Check the play of the clutch discs weekly. Access from beneath the
mesh grille. See page 23, between points 3 & 5.
Check the oil level for the diesel engine. See page 21, point 13.
Empty the compressed air system of water. See page 21, point 8.
Check the mist system’s lter before use. See
page 21, point 10.
Check the intake lter – clean if necessary, replace if required. See
page 23, point 2.
Check the oil level in the mist lubricator for compressed air. See
page 23, point 5.
Check belts for generator and vacuum cleaner.
Page 23, points 1 & 4.
Check belts for AC & fans. See gure 1, point 7.
Check the level in the cooling system – the engine must not be
running or hot. See gure 1, point 2.
Check the level in the water separator for the fuel system – must
not be more than 50%. See gure 1, point 3.
Residual current devices are activated at least every six months.
You are recommended to activate the residual current device be-
fore starting an assignment.
Miniature circuit breakers must be activated at least once a year.
You are recommended to activate the miniature circuit breakers
before starting an assignment.