Item Specification
Ambient
operating
temperature
Long-term Standard mode: 0°C to +45°C (32°F to 113°F)
Enhanced mode: -40°C to +65°C (-40°F to 149°F)
NOTE
The use of optical components may limit the ambient temperature
range.
Short-term -5°C to +55°C (23°F to 131°F)
(Short-term refers to a period of 96 consecutive hours or less
and a total of 15 days or less in a year.)
Remarks Temperature change rate limit: 30°C/hour (86°F/hour)
Storage temperature -40°C to +70°C (-40°F to 158°F)
Ambient
operating
relative
humidity
Long-term 5% RH to 85% RH, noncondensing
Short-term 5% RH to 95% RH, noncondensing
Storage relative humidity 0% RH to 95% RH, noncondensing
Long-term working altitude Lower than 3000 m (9842.4 ft)
Storage altitude Lower than 5000 m (16404 ft)
Table 2-4 Physical specifications of the CX600-X2-M8 AC
Item Specification
Dimensions (H x W x D) 442 mm x 220 mm x 264 mm (17.4 in. x 8.66 in. x 10.39 in.);
approximately 5 U (267 mm or 10.51 in.) high
Installation Can be installed in an N63B cabinet, a 19-inch standard
cabinet, or a 23-inch rack that complies with the North
American standard
Weight 25 kg (52.9 lb)
Typical power consumption 550 W
Heat dissipation 2107 BTU/hour
DC input
voltage
Rated
voltage
-48 V
Maximum
voltage
range
-38 V to -72 V
System
reliability
MTBF
(year)
138.61
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description 2 CX600-X2-M8 Hardware Description
Issue 03 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
37