2. Align the triangle hole on the CPU carrier with the triangle mark on the CPU, and place
the CPU carrier downloads. See (1) in Figure 6-28.
Figure 6-28 Installing the CPU and conjoined heat sink
3. Check that the CPU is securely installed and level with the carrier. Press down to secure
any raised parts.
Step 8 Paste thermal compound.
1. Check that the CPU surface is clean. Use a tissue to clean off any residual thermal paste.
2. Determine the area on the CPU that will be in contact with the heat sink, and evenly
paste 0.4 ml of thermal compound on the area.
NOTE
The thermal compound injector has volume marks.
Figure 6-29 shows the methods for pasting thermal compound.
Figure 6-29 Pasting methods
中间一点法 一字法 二字法
十字法 五点法 S形法
FusionServer G5500 Server
User Guide
6 Optional Part Installation
Issue 02 (2017-12-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
146