NOTE
The default value of Power Strategy is Turn on, which indicates that the compute node
automatically powers on after power is supplied to PSUs. To change the value of Power Strategy,
log in to the iBMC WebUI and choose Power > Power Control.
l If PSUs are powered on and the compute node is in the standby state, power on the
compute node as follows:
NOTE
When the power indicator is steady yellow, the compute node is in the standby state.
Press the power button on the front panel to power on the compute node. For details
about the power button position, see 2.3 Front Panel Indicators and Buttons.
Power on the compute node using the iBMC WebUI. For details, see Power on the
compute node using the iBMC WebUI.
Power on the compute node using the iBMC command-line interface (CLI) in
remote management mode.
n Log in to the iBMC CLI of the G560. For details, see 5.4.4 Logging In to the
iBMC CLI.
n Log in to the iBMC CLI of the G530 V2. For details, see 5.5.4 Logging In to
the iBMC CLI.
Run the ipmcset -d powerstate -v 1 command on the iBMC CLI to power on the
compute node remotely.
Procedure
Power on the compute node using the iBMC WebUI.
1 Log in to the iBMC WebUI of the compute node to be powered on.
To log in to the iBMC WebUI of the G560, see 5.4.1 Logging In to the iBMC WebUI.
To log in to the iBMC WebUI of the G530 V2, see 5.5.1 Logging In to the iBMC
WebUI.
2 Choose Power > Power Control.
The Power Control page is displayed, as shown in Figure 3-2.
FusionServer G5500 Server
User Guide
3 Basic Operations
Issue 02 (2017-12-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
35