No. Cable Type Conductor Cross-
Sectional Area
Range
Outer
Diameter
Termin
al
Source
2 AC
input
power
cable
Four-core/Five-
core outdoor
copper/copper-
clad aluminum/
aluminum alloy
cable
● LUNA2000-2.0M
WH-1HX: 35–185
mm
2
● LUNA2000-2.0M
WH-2HX: 10–185
mm
2
24.6–72 mm M10
OT/DT
termina
l
Prepared
by the
customer
4 FE
commu
nication
s cable
CAT 5E outdoor
shielded network
cable, internal
resistance ≤ 1.5
ohms/10 m
- < 9 mm Shielde
d RJ45
connect
or
Prepared
by the
customer
5 Optical
cable
Supports the
four-core or
eight-core
single-mode
armored cable
with the
transmission
wavelength of
1310 nm.
- ≤ 18 mm - Prepared
by the
customer
5.2 Connecting Socket Circuit Wires
Scenario 1
This procedure applies only to the models listed in the table below.
Models
Air Conditioner Position in the
Battery Cabin
LUNA2000-2.0MWH-1HX 1/3/5/7/9/11
LUNA2000-2.0MWH-2HX 1/4/7/10
● Cables 1733, 1735, 1734 and 1736 are pre-installed. Cables 1751, 1752, 1757, 1760,
2055, 2056, 1761 and 1762 need to be installed.
● The cables to be installed can be obtained from the cable binding position shown in the
gure before installing the socket.
LUNA2000-2.0MWH Series Smart String ESS